Category 6A
The Construction Products Regulation (CPR) is a "common technical language" that proposes the standardized assessment of the fire performance of building materials throughout the European region.
LS Simple provides CPR rated cables from category 5e to 6A in different types of structure to enable our customers to fulfill their requirments.
LS Simple provides CPR rated cables from category 5e to 6A in different types of structure to enable our customers to fulfill their requirments.
Category 6A

F/UTP Cat.6A LSZH Dca
Conductor: The conductors shall be solid , annealed and bare copper with a diameter of AWG23
and minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with solid high density polyethylene. and FEP for CMP cable. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Screen: The aluminum tape coated on one side with plastic film shall be applied over the core wrapping
for screening. A tinned copper wire with the diameter 0.4mm shall be applied with cable core in jacket.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the screening.
and minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with solid high density polyethylene. and FEP for CMP cable. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Screen: The aluminum tape coated on one side with plastic film shall be applied over the core wrapping
for screening. A tinned copper wire with the diameter 0.4mm shall be applied with cable core in jacket.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the screening.

U/UTP Cat.6A Ultra Super Slim LSZH Eca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG26
Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core.
Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core.

U/UTP Cat.6A Super Slim LSZH(CM) Dca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and
minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.
minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.

U/UTP Cat.6A Single Sheath LSZH Cca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23.
Insulation: Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous Shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.
Insulation: Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous Shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.

U/UTP Cat.6A Double Sheath LSZH Cca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23.
Insulation: Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous Shield: The non-continuous aluminum tape shall be applied over the core wrapping to increase alien crosstalk performances.
Insulation: Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous Shield: The non-continuous aluminum tape shall be applied over the core wrapping to increase alien crosstalk performances.

U/UTP Cat.6A Super Slim LSZH Dca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and
minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.
minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Non-continuous shield: The non-continuous aluminum tape shall be applied over the core wrapping to
increase alien crosstalk performances.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other
colors shall be applied over the cable core.

U/UTP CAT.6A 1st generation LSZH Dca
Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and minimum acceptable diameter shall be 0.546mm.
Insulation: Each conductor shall be insulated with solid high density polyethylene. The Insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey
or other colors shall be applied over the cable core.
Insulation: Each conductor shall be insulated with solid high density polyethylene. The Insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey
or other colors shall be applied over the cable core.